FLEXIM - FLUXUS G809 - Gas Flowmeter for hazardous areas - Permanent Gas Flow Meter for Hazardous Areas

Permanent Gas Flow Meter for Hazardous Areas

The ultrasonic gas flow meter for operation in hazardous areas

The FLUXUS G809 is FLEXIM's dual channel ultrasonic clamp-on flow meter for bi-directional flow measurement of gases in hazardous areas (FM Class I, Div. 1 and ATEX, IECEx Zone 1 approved).

With its flameproof housing and the corrosion resistant transducers residing inside the rugged PERMAFIX mounting fixture, ensuring a permanent contact pressure and high mechanical stability, the FLUXUS G809 series is perfectly suited for every demanding industrial application.

The FLUXUS G809 gas flow meter allows for an inherently bi-directional gas flow measurement of operational and standard volume flows. As the transducers are mounted on the outside of the pipe wall, the system does not suffer from wear and tear or clogging, can't be a risk for leaks and will not cause any pressure drops inside the pipe.

Due to its matched and paired transducers as well as the internal temperature compensation (compliant to ANSI/ASME) the measurement system is drift free and zero stable ensuring accurate readings. The gas flow meter can be applied at inner pipe diameters ranging from 0.4 inch up to 83 inches (with no limitations on pipe wall thickness or material) and media temperatures from -40 °F up to 210 °F.

With up to two measurement channels, the FLUXUS G809 permanent gas flow meter can also be applied to difficult measurement points and is completely unaffected by gas density, viscosity and composition as well as temperature and pressure.  Even wet gas up to Liquid Volume Fractions of 5% can be measured.

Permanent Gas Flow Meter for Hazardous Areas - FLUXUS G809

Advantages

  • Bi-directional flow measurement of liquids and gases in FM Class I, Div. 1 and ATEX / IECEx Zone 1 areas
  • Very cost effective: No pipe works, No process shut-downs, Virtually maintenance-free
  • Matched, paired and wet calibrated flow transducers (traceable certification to national standards)
  • Excellent zero point stability and drift-free
  • Wide turndown ratio
  • Independent of pipe size, material, operating pressure and gas composition
  • High tolerance to entrained solids and gas wetness
  • Free of wear, tear and abrasion
  • Not prone to clogging or corrosion
  • No pressure loss or source of potential leaks and fugitive emissions

Technical Facts

Operating temperature of the transmitter
-22 °F...140 °F
Degree of protection
NEMA 4X / IP66 (Transmitter) Coating for Offshore usage
Quantities of measurement
volumetric flow rate, mass flow rate, flow velocity
Optional hazardous area classification
ATEX, IECEx Zone 1, FM Class I, Div. 1
Outputs
4 (various combinations of current, binary, Modbus and HART are available)
Communication Protocol
HART, Modbus
Media temperature
-40 °F ... 390 °F
Pipe diameter range
0.4 inch ... 83 inches
Flow velocity range
0.03 ... 115 ft/s
Measurement accuracy
±0.5 % of reading ±0.03 ft/s, field calibrated, ±1% of reading ±0.03 ft/s, NIST traceable
Repeatability
±0.15% of reading ± 0.03 ft/s
Additional Notes
240V or 24V DC power supply version of the transmitter available