Permanent Gas Flow Meter for Hazardous Areas
The ultrasonic gas flow meter for operation in hazardous areas
The FLUXUS G809 is FLEXIM's dual channel ultrasonic clamp-on flow meter for bi-directional flow measurement of gases in hazardous areas (FM Class I, Div. 1 and ATEX, IECEx Zone 1 approved).
With its flameproof housing and the corrosion resistant transducers residing inside the rugged PERMAFIX mounting fixture, ensuring a permanent contact pressure and high mechanical stability, the FLUXUS G809 series is perfectly suited for every demanding industrial application.
The FLUXUS G809 gas flow meter allows for an inherently bi-directional gas flow measurement of operational and standard volume flows. As the transducers are mounted on the outside of the pipe wall, the system does not suffer from wear and tear or clogging, can't be a risk for leaks and will not cause any pressure drops inside the pipe.
Due to its matched and paired transducers as well as the internal temperature compensation (compliant to ANSI/ASME) the measurement system is drift free and zero stable ensuring accurate readings. The gas flow meter can be applied at inner pipe diameters ranging from 0.4 inch up to 83 inches (with no limitations on pipe wall thickness or material) and media temperatures from -40 °F up to 210 °F.
With up to two measurement channels, the FLUXUS G809 permanent gas flow meter can also be applied to difficult measurement points and is completely unaffected by gas density, viscosity and composition as well as temperature and pressure. Even wet gas up to Liquid Volume Fractions of 5% can be measured.

Advantages
- Bi-directional flow measurement of liquids and gases in FM Class I, Div. 1 and ATEX / IECEx Zone 1 areas
- Very cost effective: No pipe works, No process shut-downs, Virtually maintenance-free
- Matched, paired and wet calibrated flow transducers (traceable certification to national standards)
- Excellent zero point stability and drift-free
- Wide turndown ratio
- Independent of pipe size, material, operating pressure and gas composition
- High tolerance to entrained solids and gas wetness
- Free of wear, tear and abrasion
- Not prone to clogging or corrosion
- No pressure loss or source of potential leaks and fugitive emissions
Applications
- Oil & Gas
- Upstream / Offshore Solutions
- Onshore / Shale Oil & Gas Solutions
- Underground Gas Storage & Processing
- Oil & Gas Storage and Distribution
- Refinery Solutions
- Upstream / Offshore Solutions
- Chemical Industry
- Polymer Production
- Base & Intermediate Chemicals
- Acid and Caustics Production
- Polymer Production
Technical Facts
- Measurement uncertainty
(volumetric flow rate) - ± 1...3 % of reading ±0.02 ft/s
- Repeatability
- 0.15 % of reading ±0.02 ft/s
- Flow velocity range
- 0.03 to 115 ft/s, depending on pipe diameter
- Ex zone transmitter
- ATEX/IECEx Zone 1
FM Class I - Div1 - Power supply
- 100-230VAC, 24DC
- Available transducer
- Shear wave/Lamb wave
- for Ex zones
- ATEX/IECEx Zone 1
FM Class I - Div1 - for pipe sizes range
- 0.28 inch to 63 inch
- for temperature range
- -40°F to +392°F
- Outputs
- 4-20mA active/passive
4-20mA HART active/passive
4-20mA passive intrinsic safety
pulse/frequency/binary - Inputs
- ---
- Digital communication
- Modbus RTU
- Additional Information
- For more detailed Information please download the Technical Specifications
360° view