Обзор

The FLUXUS F722 liquid flow meter is a high performer ultrasonic clamp on meter specifically designed for measurement of dynamic flows in the process industry. This sophisticated, versatile, and accurate flow meter has everything you need - faster processing capabilities, advanced diagnostics, bidirectional communication protocols, digital outputs, and process inputs. In keeping with all other Flexim products, the F722 offers ease of installation, retrofittable design, accuracy, and outstanding performance.  

Synchronized Channel Averaging (SCA)

In multi-channel flow measurement lag time (delay) between signal acquisitions from each channel and data averaging are often longer than the time required for process control applications - depending on the specified sampling rate, a flow meter can take anywhere from 1 to 20 seconds to complete processing cycles and report the current flow rate.  In constant flows, where rapid changes in flow are not found, flow updates at the above intervals is acceptable.  However, this is not the case in control applications where rapid changes in flow must invoke immediate responses from the control system.  

In these cases, response time expectations and requirements are higher. Using the new Synchronized Channel Averaging method (SCA), the F722 ultrasonic flow meter sends signals both in the direction of the flow and against the flow every 1millisecond. These signals are averaged simultaneously resulting in better flow profile representation, a more stable output and minimizing cross flow effects in highly dynamic flows with demanding inflow conditions.

The FLUXUS F722 is available both in Aluminum and Stainless-Steel housing options, with ATEX/IECEx Zone 2 and FM Class 1, Div. 2.

Additional advantages of the system are; temperature compensated transducers, superior noise suppression and a rugged and user-friendly design that offers an unmatched degree of reliability, durability, and accuracy - ensuring perfect operation of the system under the harshest field conditions.

Преимущества

  • Synchronized Channel Averaging Fast measurement dynamics and stable output even under undesirable inlet conditions and dynamic flows
  • Accuracy and repeatability – exceptional reliability and accuracy at high and low flows due to matched, calibrated and temperature compensated transducers, advanced signal processing capabilities and diagnostics.
  • Easy installation without process interruptions – An externally mounted system means no need for process interruptions or additional engineering costs.
  • Maintenance Free – No contact with flowing media results in a completely maintenance free and durable metering solution suitable to withstand the harshest environments.
  • Operational Safety No leak paths, no fugitive emissions
  • AMV Logo

Загрузки

Технические данные

Погрешность измерения в точке измерения (объемный расход)
± 1 ... 2% of reading ± 0.005 m/s
Повторяемость
0.15 % of reading ±0.005 m/s
Диапазон скорости потока
0.01...35 m/s, depending on pipe diameter
Преобразователь взрывоопасной зоны
ATEX/IECEx Zone 2
Источник питания
100-230VAC, 24DC, 12DC
Доступный датчик
Shear wave/Lamb wave
для взрывоопасных зон
ATEX/IECEx Zone 1/Zone 2
FM Class I - Div2
для диапазона размеров труб
7 mm ... 1600 mm
для диапазона температур
-40°C ... +240°C / WI: -200°C ... +630°C
Выходы
4-20mA active/passive
4-20mA HART active/passive
pulse/frequency/binary (digital)
Входы
Pt100/Pt1000
4-20mA active/passive
Binary input
Цифровая связь
Modbus RTU/TCP
BACnet MSTP/IP
Profibus PA
Foundation Fieldbus
Advanced Meter Verification (AMV)
доступна
Дополнительная информация
For more detailed Information please download the Technical Specifications