FLEXIM - FLUXUS Semiconductor - F501SC - Non-invasive Ultrasonic Flow Meter for the Semiconductor Industries - Non-invasive Ultrasonic Flow Meter for the Semiconductor Industries

Non-invasive Ultrasonic Flow Meter for the Semiconductor Industries

One of the highest priorities within cleanroom environments is to avoid potential contamination of flowing media - such as ultrapure or deionized water, cleaning agents, solvents as well as acids and caustics - through dissolved metals.

FLEXIM thus developed a non-invasive ultrasonic meter that is ideally suited for such applications:

The FLUXUS Semiconductor is engineered and manufactured without any metal components. Further, as it is mounted outside the elastic tube or pipe, there is no intrusion, no direct media contact and thus never a possibility for any leaks or contamination. Moreover, costly process stops for installation are not necessary and the system itself is virtually maintenance-free.

Reliability and accuracy are one of FLEXIM’s cornerstones. The FLUXUS semiconductor is no exception – even when mounted on elastic tubes. A special fixture ensures a stable and durable mounting, allowing for an unrivalled precision over many years.

Thus, the FLUXUS Semiconductor is the ideal flow meter for an economic operation within cleanroom environments by accurately, reliably and safely monitoring the consumption and flow rates of any flowing media – even at very low flow rates down to several liters per hour.

Non-invasive Ultrasonic Flow Meter for the Semiconductor Industries - FLUXUS Semiconductor - F501SC

Vantagens

  • No risk of contaminating the high-purity fluids, thanks to the non-invasive, metal-free clamp-on flow measurement
  • No pipe work required to install the measuring systems - also suitable for flexible tubing
  • Non-invasive measurement is insensitive to chemically aggressive acids or solid particles
  • Process optimization thanks to exact balancing of consumption values
  • Highly accurate and reliable - also at very low flow rates

Aplicações

Características Técnicas

Incerteza de medição
(caudal volumétrico)
±1.5 % v. MW ±0.01 m/s
Repetibilidade
0.25 % v. MW ±0.01 m/s
Fluxo faixa de velocidade
0.01...25 m/s
Transmissor de zona Ex
only safe area
Fonte de energia
230VAC, 12/24VDC
Transdutor disponível
Shearwave
para zonas Ex
---
para a gama de tamanhos de tubos
8mm ... 51mm
para faixa de temperatura
-20°C .... 100°C
Saídas
1x 4-20mA active
2x pulse/binary
Insumos
---
Comunicação digital
Modbus RTU
BACnet MS/TP
M-Bus

360° view

0%

Para a visualização manual em 360 °, puxe a imagem para a esquerda ou para a direita

Downloads

FLUXUS F501SC

Especificação técnica
Scroll to top