Mass Flow, Density and Concentration Measurement without media contact

PIOX S721 determines mass flow rate, concentration, density and other parameters by means of clamp-on ultrasonic transducers mounted on the outside of the pipe. The non-invasive acoustic technology is the system of choice when substances and processes place highest demands on safety and reliability.

Indestructible as a matter of principle

In a large number of binary media systems, the acoustic velocity is in a fixed proportion to concentration and density. PIOX S721 measures the acoustic velocity, thereby determining the density and concentration of the medium inside the pipe. By simultaneously recording the volume flow rate, PIOX S721 automatically calculates the mass flow rate.

Unlimited applications

  • For virtually all pipe sizes and materials – regardless of whether it‘s steel, plastic, glass or special materials with coatings
  • For temperatures up to 400 °C
  • For almost all acids, caustics and a wide range of other toxic media
  • For hazardous areas – transducers and transmitters are available in ATEX, IECEX and FM certified variants
  • For 100% plant availability – the measurement point can be set up during ongoing operation

The ideal "Outsider"

The PIOX S measuring system, composed of a transmitter and a pair of clamp-on transducers, precisely determines the sonic velocity of the medium based upon the ultrasonic transit-time measured between the two transducers.The clamp-on transducers are mounted on the outer surface of the pipe. As they are not in contact with the medium, the system is ideally suited for the measurement of chemically aggressive, corrosive, abrasive or ultra-pure media.

PIOX S can be used to determine the concentration of high purity sulfuric acid, hydrofluoric acid, nitric acid or even ammonia gas used in fertilizer plants. Worries about the transducers chemical compatibility, contamination and sealing are a thing of the past.

With the clamp-on technology, retrofitting of existing installations is very easy and can be done without cutting into the pipe and without any process interruption.

Concentration and Mass Flow Measurement by Ultrasound - PIOX S

Voordelen

  • Non-Intrusive, Installation without process interruption (clamp-on)
  • No contact with the medium, no special materials necessary
  • Hygenic measurement method, suitable for ultrapure media
  • No pressure loss, no risk of leakage, no contamination
  • No chemical compatibility issues, , watertight, no pressurized parts
  • Maintenance free, no corrosion or abrasion
  • Integrated, highly dynamic flow measurement

Technische feiten

Meetonzekerheid
(Luchtvolumestroom)
±1 % of reading ±0.005 m/s
Herhaalbaarheid
0.15 % of reading ±0.005 m/s
Stroom snelheid bereik
0.01...25 m/s
Ex-zonezender
ATEX/IECEx Zone 2, FM Class I /Div 2
Voeding
100-230VAC, 24DC, 12DC
Beschikbare omvormer
Shear wave
voor Ex-zones
---
voor pijpmatenbereik
10mm ... 6500mm
voor temperatuurbereik
-40°C ... +240°C / WI: -200°C ... +600°C
Uitgangen
4-20mA active/passive
4-20mA HART active/passive
pulse/frequency/binary
Ingangen
Pt100/Pt1000
4-20mA active/passive
Binary input
Digitale communicatie
Modbus RTU/TCP
BACnet MSTP/IP
Profibus PA
Foundation Fieldbus

360° view

0%

Voor het handmatige 360 ° -beeld trekt u het beeld naar links of naar rechts

Downloads

PIOX S - Non-intrusive concentration, density and mass flow measurement

Brochure

PIOX S721

Technical specification