Aperçu général
The World‘s Only Clamp-On Steam Meter: FLUXUS ST-LT
FLEXIM has been setting standards for 30 years, and with the FLUXUS ST steam meter series, boundaries for non-invasive measuring technology have been pushed again.
Non-invasive and efficient
FLUXUS ST-LT measures steam flow non-invasively from the outside of the pipe. Non-invasive steam flow measurement means measuring without any interruption of operation and supply. Since clamp-on ultrasonic transducers are simply mounted on the outside of the pipe, it requires just minimal installation effort and no opening of the pipeline.
The acoustic measuring method proves to be impressive with its exceptionally high measuring dynamics, is highly sensitive even at very low flow velocities and functions independently of the flow direction. Due to this large flow range (flow velocities from 0.01 m/s up to 60 m/s), there is no need to reduce pipe diameter to fit an inline meter’s requirement of minimum flow velocity. Moreover, the non-invasive measurement does not cause any pressure loss. The transducer mountings can be completely insulated to reduce any heat loss to the environment.
With FLUXUS ST-LT, for the first time ever, it is possible to capture all steam usage from very low to very high flow rates with one meter size.
Completely maintenance-free
Non-invasive steam flow measurement also means measuring without direct contact with the medium flowing in the pipe. FLUXUS ST has no moving parts. Therefore, FLUXUS ST-LT is not subjected to wear and tear and does not require any maintenance.
FLUXUS ST-LT measures volume and mass flow of saturated and superheated steam at temperatures up to 180 °C. The clamp-on ultrasound system is available as both a stationary and a portable meter.
Fixed and versatile
FLUXUS G722 ST-LT is a fixed installed flow meter for steam and offers a variety of digital communication interfaces such as Profibus, Modbus TCP and others.
100% process availability is guaranteed when using a FLEXIM solution – the installation of a FLUXUS G722 ST-LT does not disturb the steam process itself at any time.
Applications industrielles
Gestion de l’énergie flexible et non intrusive
Gestion de l’énergie flexible et non intrusive

Mesure non intrusive de la vapeur
Mesure non intrusive de la vapeur

Gestion de l’énergie flexible et non intrusive
Gestion de l’énergie flexible et non intrusive

Mesure non intrusive de la vapeur
Mesure non intrusive de la vapeur

Fiche Technique
max. 165°C ATEX Zone 2
max. 155°C ATEX Zone 1
ATEX / IECEx Zone 2
Transducers:
ATEX / IECEx Zone 1 or Zone 2