Mass Flow, Density and Concentration Measurement without media contact

PIOX S721 determines mass flow rate, concentration, density and other parameters by means of clamp-on ultrasonic transducers mounted on the outside of the pipe. The non-invasive acoustic technology is the system of choice when substances and processes place highest demands on safety and reliability.

Indestructible as a matter of principle

In a large number of binary media systems, the acoustic velocity is in a fixed proportion to concentration and density. PIOX S721 measures the acoustic velocity, thereby determining the density and concentration of the medium inside the pipe. By simultaneously recording the volume flow rate, PIOX S721 automatically calculates the mass flow rate.

Unlimited applications

  • For virtually all pipe sizes and materials – regardless of whether it‘s steel, plastic, glass or special materials with coatings
  • For temperatures up to 400 °C
  • For almost all acids, caustics and a wide range of other toxic media
  • For hazardous areas – transducers and transmitters are available in ATEX, IECEX and FM certified variants
  • For 100% plant availability – the measurement point can be set up during ongoing operation

The ideal "Outsider"

The PIOX S measuring system, composed of a transmitter and a pair of clamp-on transducers, precisely determines the sonic velocity of the medium based upon the ultrasonic transit-time measured between the two transducers.The clamp-on transducers are mounted on the outer surface of the pipe. As they are not in contact with the medium, the system is ideally suited for the measurement of chemically aggressive, corrosive, abrasive or ultra-pure media.

PIOX S can be used to determine the concentration of high purity sulfuric acid, hydrofluoric acid, nitric acid or even ammonia gas used in fertilizer plants. Worries about the transducers chemical compatibility, contamination and sealing are a thing of the past.

With the clamp-on technology, retrofitting of existing installations is very easy and can be done without cutting into the pipe and without any process interruption.

Concentration and Mass Flow Measurement by Ultrasound - PIOX S

Avantages

  • Non-intrusif, Installation sans interruption de process

  • Pas de contact avec le fluide

  • Méthode de mesure hygiénique, adaptée aux milieux ultrapures

  • Pas de perte de charges, pas de risque de fuite, pas de contamination

  • Aucun problème de compatibilité chimique, étanche, aucune pièce sous pression

  • Sans entretien, sans corrosion ni abrasion

Fiche Technique

Measuring quantities
(temperature compensated) w%, ° Brix (Plato, Oechsle) additional quantities programmable
Vitesse d'écoulement
0,01 ... 25 m/s
Plage de diamètre
6mm ... 6500mm (no limitation on wall thickness and materials)
Précision de la mesure
Concentration and Density: up to 0.1% of reading (depending on media, concentration and temperature range)
Précision de la mesure
(calibration avancée)
Massflow: ±1.2 % of reading ±0.01 m/s
Précision de la mesure
(calibration en ligne)
Massflow: ± 0.5% of reading ±0.01 m/s
Operating temp. (media)
- 40 °C ... + 200 °C
(-190 °C ... + 400°C with WaveInjector)
Plage de température du débitmètre
PIOX S704: -20 °C... + 60 °C
PIOX S705: -40 °C... + 60 °C
Degré de Protection
Transducers: IP65 to IP68, optional ATEX (IECEx) Zone 2 / FM Class I, Div. 2 Transm.: PIOX S704: IP65, ATEX (IECEx) Zone 2 opt.
Explosion protection
PIOX S705: IP66, stainless steel enclosure, ATEX (IECEx) Zone 2 and FM Class I, Div. 2 optional PIOX S709: 19 inch rack version
Protocole de communication
HART, ModBus, Foundation Fieldbus
Sorties
A variety of combinations are available from the following: current (0/4 mA ... 20 mA), voltage, frequency, pulse, alarm
Inputs
Maximum 4, Available are: Temperature (PT 100 4-wire), current, voltage

360° view

0%

Pour la vue manuelle à 360 °, tirez l'image à gauche ou à droite

Téléchargements

PIOX S - Fini les corrosions et les usures mécaniques

Brochure

PIOX S70x

Spécification technique
Scroll to top