FLEXIM - FLUXUS Cryo - Non-invasive flow measurement of cryogenic fluids - Non-invasive flow measurement of cryogenic fluids

Non-invasive flow measurement of cryogenic fluids

The superior measuring solution for cryogenic fluids

Since years FLEXIM’s unique non-invasive ultrasonic flow meters have been running in various LNG and other cryogenic applications at temperatures down to -200 °C: from 3” lines in peak shaving plants to 36" pipes for tanker off-loading to storage tanks.

The non-invasive ultrasonic flow meters provide the ideal solution for all cases where reliable and trouble-free flow measurement of cryogenic fluids is required. With its huge measurement range FLUXUS Cryo is ideally suited to cover the highest flow rates of loading / off-loading processes as well as very low flow rates at start or stop of operation.

As the system measures from outside the pipe wall, installation does not require any pipe cutting or extensive pipe works. Further, FLUXUS Cryo is virtually maintenance free, does not cause any pressure drops and can never be the source for potential leaks.
With its unrivalled accuracy and reliability, FLUXUS Cryo meets all requirements for regular monitoring, control as well as SIS purposes. The implemented diagnostics can be used to detect beginning and end of the cryogenic liquid flows in batch processing.

Features:

  • Highly accurate flow measurement of LNG, Liquid Ethane, Liquid Air, Nitrogen and Oxygen without any pressure drops
  • Highly reliable:
    - Maintenance-free. No moving or vibrating parts
    - Dual-beam redundant measurements
  • Operationally safe:
    - No gaskets, No leakage points
  • Economic:
    - No pipework modification necessary
    - One-man-installation without the need for lifting gear
    - No pressure loss - no chance for flashing

 

Non-invasive flow measurement of cryogenic fluids - FLUXUS Cryo

ventajas

Retrofit Applications:

  • No pipework necessary
  • No lifting gear required – independent of pipe size
  • FLUXUS Cryo can be mounted at limited space conditions, e.g. at FLNG loading arms
  • Installation is done within a few hours when the pipe is not cooled down
  • The measuring system is fully integrated into the insulation

New Plants:

  • Highly cost-effective - only standard piping needs to be planned – FLUXUS Cryo fits
  • Late design changes aren‘t a problem! One equipment type fits many pipe sizes
  • No pressure-loss and thus no energy loss
  • No chance to cause flashing
  • Significantly reduced CAPEX, especially for large diameters
  • Global installation and support by FLEXIM

Aplicaciones

Hechos técnicas

Canales de flujo
1 ( optional 2)
Cantidades de medición
Volume flow, mass flow, flow velocity
Medio
Cryogenic Fluids (LNG, Liquid Ethane, Liquid Air, Nitrogen, Oxygen and others)
Alcance de volocidad de flujo
0.01m/s ... 25 m/s
Precisión de medición
(estándar)
±1.2% of reading, ±0.01 m/s
Precisión de medición
(campo calibrado)
±0.5% of reading, ±0.01 m/s
Repetibilidad
±0.15% of reading, ±0.01 m/s
Temperatura del medio
-200°C ... +80°C
Temperatura de funcionamiento del transmisor
-40°C ... +60°C
Alcance del diámetro de la tubería
70 mm to 1000 mm
Grado de protección
Transmitter: IP66, Transducers: up to IP68
Certificados disponibles para la protección contra explosiones (opcional)
ATEX / IECEx Zone 1 / 2; FM Class I, Div. 1 / 2
Protocolo de comunicación
HART, Modbus RTU/TCP, RS485, Profibus PA, Foundation Fieldbus
USB and Ethernet interface for communication available
Entradas
Depending on Transmitter: Up to 4 Inputs (temperature Pt100/Pt1000), current, voltage, binary
Salidas
Depending on Transmitter: Up to 4 Outputs: (active/passive) current, voltage, frequency, binary