Demonstration measurement at your site

Assure yourself of the advantages and superior performance of our non-invasive metering technology with a non-committal demonstration at your site. There are no prerequisites and the demonstration with one of our portable solutions will only take a few minutes of your time.

A brief description of your application would be helpful for us. Additional comments and a preferred date and time for the demonstration are always welcome:

FLEXIM - FLUXUS XLF - Xtra Low Flow Meter - Non-invasive Flow Meter for Extremely Low Flow rates

Non-invasive Flow Meter for Extremely Low Flow rates

Do you need to measure really low flows? Turn to FLUXUS XLF

FLUXUS XLF is FLEXIM‘s non-invasive metering system for the reproducible and long term reliable measurement of extremely low flow rates down to 3 l/h and below on line sizes ranging from 10 mm to 50 mm independent of the pipe wall thickness. As the flow sensors are mounted externally, there is no process interruption for installation.

Moreover, due their IP66 protection degree, ATEX / IECEx Zone 1 / 2 as well as FM Class I, Div. 1 / 2 approval and being completely made out of stainless steel (316L / 1.4404 grade), the measurement system is highly rugged and withstands even the harshest and most corrosive environmental conditions.

FLEXIM is the much more cost-effective and safer alternative for measuring extremely low flows of any liquid

The FLUXUS XLF is applicable on all pipe materials and wall thicknesses as well as independent of operating pressures.
In comparison to wetted instrumentation, the system does not suffer from mechanical stress or wear and tear by the medium and is thus not only much more cost efficient, but also offers significantely higher operational safety as the risk of leaks can completely be eliminated.

Its high accuracy and repeatability at extremely low flow velocities is achieved by carefully matched and temperature compensated transducers (acc. to ANSI/ASME MFC 5.1-2011), highly sensitive electronics and sophisticated internal signal processing as well as a highly precise and traceable wet flow calibration (according to NIST standards) at FLEXIM‘s low flow calibration facility.

Non-invasive Flow Meter for Extremely Low Flow rates - FLUXUS XLF

Advantages

  • No process shut-downs or interruption of supply
  • No potential for leaks
  • Completely maintenance free
  • Accurate and highly repeatable measurement of extremely low flows
  • Applicable to any pipe and any liquid media
  • Rugged and hazardous area approved transducers and transmitters (ATEX /  IECEx Zone 1/2, FM Class I, Div. 1/2)
  • Matched transducers, advanced digital signal processing (DSP) and efficient algorithms ensure stable measurements at very low flows

Applications

Technical Facts

Flow channels
1
Operating temperature of the transmitter
-40 °C ... +60 °C
Degree of protection
IP66
Functional Safety (acc. to IEC / DIN EN 61508)
SIL2
Optional hazardous area classification
ATEX / IECEx Zone 1 and 2, FM Class I, Div. 1 / 2
Outputs
A variety of combinations are available from the following: current (0/4 mA ... 20 mA), voltage, frequency, pulse, alarm
Inputs
Maximum 4, Available are: Temperature (PT 100 4-wire), current, voltage
Communication Protocol
HART or Foundation Fieldbus or ModBus RTU or RS485 or BACNet MS/TP
Media temperature
-40 °C ... +200 °C
Pipe diameter range
10 mm ... 50 mm (independent of material and wall thickness)
Flow velocity range
> 0,003 m/sec (at stable media temperatures flows as low as 0,001 m/sec can accurately be monitored)
Calibrated accuracy
± 1,2% of reading, ± 0,01 / (N x ID) [m/s] N = number of soundpaths, ID = inner diameter in [inch]

360° view

0%

For the manual 360° view pull the image left or right

Downloads

FLUXUS F70xLF

Technical Specification

FLUXUS F80X Application Low Flow

Technical Specification

FLUXUS XLF - Non-invasive Flow Meter for Extremely Low Flow rates

Brochure
Scroll to top