Demonstration measurement at your site

Assure yourself of the advantages and superior performance of our non-invasive metering technology with a non-committal demonstration at your site. There are no prerequisites and the demonstration with one of our portable solutions will only take a few minutes of your time.

A brief description of your application would be helpful for us. Additional comments and a preferred date and time for the demonstration are always welcome:

Technical Data

P/N 610007AB and P/N 610007MB (GST 6108 and GST 6108M) Leakage Meter

Measuring principle: ultrasonic transit-time difference principle
Flow velocity: (0.01 to 25) m/s [(0.03 to 82) ft/s]
Resolution: 0.025 c m/s [0.0008 ft/s]
Repeatability: 0.15% of read. ± 0.01 m/s [0.15% of read. ± 0.03 ft/s]
Accuracy (for fully developed, rotationally symmetrical flow profile)
- Volume flow: ± 1% to 3% of read. ± 0.01 m/s [± 1% to 3% of read. ± 0.03 ft/s]
  depending on application
  ± 0.5% of reading ± 0.01 m/s [± 0.5% of read. ± 0.03 ft/s]
  with process calibration
- Path velocity: ± 0.5 % of read. ± 0.01 m/s [± 0.5 % of read. ± 0.03 ft/s]
Accuracy at the defined test (flow profile not rotationally symmetrical)
points for a leakage measurement  
- Volume flow: < 7% of read. ± 0.01 m/s
for T = 10 °C to 60 °C
[< 7% of read. ± 0.03 ft/s]
[for T = 50 °F to 140 °F]
Transmitter
Enclosure
- Weight: approx. 3.9 kg* [approx. 8.6 lb]
- Deg. of protection: IP54 acc. to EN60529 [NEMA 3S]
- Material: aluminium, epoxy coated
- Dimensions (with handle): (276 x 118 x 317) m [(10.87 x 4.64 x 12.48) in]
Measuring channels: 1
Power supply: Rechargeable battery (6v /4 Ah) or external power supply (100-240) AC
Operating time with battery: ›10 h
Charge time for max. capacity: 15 h
Display: 2 x 16 characters, dot matrix, backlit
Operating temp.: -10 °C to 60 °C [14 °F to 140 °F]
Power consumption: < 15 W
Measuring cycle: (100 to 1000) Hz (1 channel)
Measuring functions
Meas. quantity: volume flow
Meas. units: l/min or gal/min
Data logger
Loggable values: all measured values
Capacity: meas. values: ›100 000
meas. series: 99
Communication
Interface: RS232
Data: actual meas. value, logged data, parameter records
Leakage transducer
Rated (possible)diameter range: (9 to 25.4) mm [(3/8 to 1) in]
Dimensions, W x H x D:
(without fastening strap)
(75 x 41 x 43) mm [(2.95 x 1.61 x 1.69) in]
Material: denclosure: stainless steel, contact surface: PEI
Operating temp: -30 °C to 130 °C [-22 °F to 266 °F]
Deg. of protection: IP65 acc. to EN60529 [NEMA 4X]

Download

Technical Specification GST 6108

PDF | 1.4MB

Technical Specification GST 6108M

PDF | 1.4MB

Ground Instruction Manual GST 6108

PDF | 1.4MB

Ground Instruction Manual GST 6108M

PDF | 1.4MB