FLEXIM - FLUXUS WW - Efficiency in monitoring wastewater flows

Efficiency in monitoring wastewater flows

For monitoring pump efficiency, controlling flow rates, and managing heavy rainfall events

Operators of sewage networks and treatment plants are striving to improve the energy efficiency of their systems. With pumps consuming a large amount of electrical energy, there is a strong demand to monitor and control the flow in pumping stations more accurately.

A further reason to equip pumping stations with flow meters is to be able to react effectively in the event of heavy rainfall. In such cases sewage levels at pumping stations can rapidly reach critical levels and operators need to know exactly how much each pump in their system is transporting in order to take appropriate action.

The FLUXUS WW is the ideal flow meter for retrofitting at pumping stations and treatment plants. It is installed without pipe modification, intrusion or process interruption, is maintenance-free and delivers accurate and reliable flow measurements.

For installations in wet well and other locations with potentially explosive atmosphere, transducers with ATEX Zone 1 approval and IP68 protection can be supplied.

The chemical composition of wastewater promotes the formation of scaling and fat deposits. Due to its higher solid content, especially sand, wastewater can also be abrasive. The clamp-on ultrasonic transducers of the FLUXUS WW series, however, are not impaired by scaling, fat deposits or abrasion and therefore the measurements remain permanently drift-free.

The advanced signal evaluation and noise reduction technology of the FLUXUS WW makes it capable of measuring fluids with high gas or solid content (up to 10% in volume), such as return activated sludge (RAS). The FLUXUS WW also measures flow in large PCCP or GRP pipes, which are composed of several layers of material and can have wall thicknesses of several centimeters.

Efficiency in monitoring wastewater flows - FLUXUS WW

优点

  • Very low installation costs, highly cost-effective
  • Maintenance-free
  • Non-intrusive, no process interruption for installation - easy retrofit
  • Measures fluids with gas or solid content of up to 10%
  • Suitable for disturbed flow profiles as well as very short inlet and outlet straight lengths
  • Permanently drift-free

技术参数

管径范围
up to 6500 mm
Pipe material
All
介质
Water / Wastewater
Solid or gas content
up to 10 % in volume
流速范围
0.01...25 m/s
精度
±0.5% of reading ± 0.01 m/s (field calibrated)
±1% of reading ±0.01 m/s
(out of the box - application dependent)
重复性
0.15 % of reading ±0.01 m/s
防护等级 传感器
IP68 and ATEX zone 1 optional
防护等级 (变送器)
IP65
流量通道
2
通信接口
RS232, Modbus RTU
数据记录器容量
> 100,000 values
输出
2x Current, 3x Binary