FLEXIM - FLUXUS G809 - Permanent Gas Flow Meter for Hazardous Areas

Permanent Gas Flow Meter for Hazardous Areas

The ultrasonic gas flow meter for operation in hazardous areas

The FLUXUS G809 is FLEXIM's dual channel ultrasonic clamp-on flow meter for bi-directional flow measurement of gases in hazardous areas ( ATEX, IECEx Zone 1 and FM Class I, Div. 1 / 2 approved).

With its flameproof housing and the corrosion resistant transducers residing inside the rugged VARIOFIX C mounting fixture, ensuring a permanent contact pressure and high mechanical stability, the FLUXUS G809 series is perfectly suited for every demanding industrial application.

The FLUXUS G809 gas flow meter allows for an inherently bi-directional gas flow measurement of operational and standard volume flows. As the transducers are mounted on the outside of the pipe wall, the system does not suffer from wear and tear or clogging, can't be a risk for leaks and will not cause any pressure drops inside the pipe.

Due to its matched and paired transducers as well as the internal temperature compensation (compliant to ANSI/ASME) the measurement system is drift free and zero stable ensuring accurate readings. The gas flow meter can be applied at inner pipe diameters ranging from 6 mm up to 2100 mm (with no limitations on pipe wall thickness or material) and media temperatures from -40°C up to 100°C.

With up to two measurement channels, the FLUXUS G809 permanent gas flow meter can also be applied to difficult measurement points and is completely unaffected by gas density, viscosity and composition as well as temperature and pressure.  Even wet gas up to Liquid Volume Fractions of 5% can be measured.

Permanent Gas Flow Meter for Hazardous Areas - FLUXUS G809

优点

  • Bi-directional flow measurement of liquids and gases in FM Class I, Div. 1 and ATEX / IECEx Zone 1 areas
  • Very cost effective: No pipe works, No process shut-downs, Virtually maintenance-free
  • Matched, paired and wet calibrated flow transducers (traceable certification to national standards)
  • Excellent zero point stability and drift-free
  • Wide turndown ratio
  • Independent of pipe size, material, operating pressure and gas composition
  • High tolerance to entrained solids and gas wetness
  • Free of wear, tear and abrasion
  • Not prone to clogging or corrosion
  • No pressure loss or source of potential leaks and fugitive emissions

技术参数

测量不确定度
(体积流量)
±1...3 % of reading ±0.005 m/s
重复性
0.15 % of reading ±0.005 m/s
流速范围
0.01...35 m/s, depending on pipe diameter
防区发射机
ATEX/IECEx Zone 1
FM Class I - Div1
供电电源
100-230VAC, 24DC
可用传感器
Shear wave/Lamb wave
对于防爆区
ATEX/IECEx Zone 1
FM Class I - Div1
适用于管道尺寸范围
7mm ... 1600mm
适用于温度范围
-40°C ... +240°C / WI: -200°C ... +600°C
输出
4-20mA active/passive
4-20mA HART active/passive
4-20mA passive intrinsic safety
pulse/frequency/binary
输入
---
数字通信
Modbus RTU
附加信息
For more detailed Information please download the Technical Specifications

360° view

0%

对于手动360°视图,向左或向右拉动图像

下载

FLUXUS G809

技术规范

FLUXUS F/G80X - For Operation in Hazardous Areas

宣传册