- About Us
- News & Exhibitions
- Ultrasonic Flowmeters
- Leading Flow Technology
- Your Advantages
- Flowmeters for Liquids
- The multifunctional portable flow meter - F601
- The portable meter for hazardous areas - F608
- The economic water meter - ADM 5107
- The permanent meter for all liquids - ADM 7407
- The permanent Rack flow meter - ADM 7907
- The permanent meter for hazardous areas - ADM 8027
- The permanent meter for Offshore environments - ADM 8127
- Flowmeters for Gases
- The portable gas flow meter - G601
- The portable gas and liquids flow meter - G601 CA Energy
- The portable gas flow meter for hazardous environments - G608
- The permanent gas flow meter - G704
- The permanent Rack gas flow meter - G709
- The permanent gas flow meter for hazardous areas - G800
- The permanent gas flow meter for Offshore environments - G801
- BTU - Thermal Energy Metering
- Process Analysis
- FLEXIM Oil & Gas
- Refinery
- State-of-the-Art
- Advantages & Benefits
- Field-Proven Worldwide
- Heavy Crude Oil flow measurement
- Overflash Mass Flow Measurement at 720°F
- Heat Transfer Oil at High Temperatures
- Heavy Gasoil in Vacuum Destillation Tower
- Fluidized Catalytic Cracker
- Highly Viscous Coker and Visbreaker Feed
- Hot Pitch During the Distillation of Coal Tar
- Measurement of Bitumen at 700°F
- Bitumen at Oil Sand Facility
- Portable Measurement of Different Media
- High Temperature Coker Control
- Underground Gas Storage
- Upstream / Offshore
- Refinery
- Service & Documents
- Contact
FLEXIM's Wet Flow Calibration Laboratory
Wet Flow Calibration Laboratory
Flexim Americas Corporation flow calibration laboratory is situated in the Edgewood, New York production space. It is a closed-loop, computer-controlled flow loop comprised of two measurement sections (2” and 6”). These precision pipes have been well characterized, equipped with Vortab and CSA Plate conditioning elements and feature well over 30 diameters of straight pipe run, assuring well-developed and symmetrical flow profile characteristics at the measurement points.
Each of the two loops is double-valve isolatable and supported by pairs of ultra-high precision electro-magnetic flow meters, annually calibrated to NIST standards by the manufacturer. The station’s computer program monitors their outputs and logs reference totals for each calibration run. In addition, the computer commands a VFD drive for closed-loop control of each flow rate being calibrated. The station is able to hold each rate to better than 0.1% of the rate commanded.
Based on the characteristics of the reference meters, it is calculated and empirically measured that the repeatability of the station is on the order of 0.25% approximately. Sources of error include residual flow profile asymmetries and the repeatability of the Yokogawa reference meters themselves. Between annual calibration intervals, the reference meters are run against each other to assure that defective calibrations do not slip through.
Please contact your local Flexim Representative
or call Flexim at 631-492-2300
FLEXIM AMERICAS CORPORATION