Unique Features of FLEXIM’s FLUXUS G gas flow meter series:

  • Every set of transducers is wet-calibrated and supplied with a traceable calibration certificate
  • Capable of measuring wet gas
  • Virtually maintenance-free due to permanent coupling pads
  • Transmitter supports both shear wave and Lamb wave transducers
  • Compliant with ANSI/ASME MFC-5M-1985(R2001) (temperature compensation)
  • Up to 1000 measuring cycles per second guarantee stable and precise flow readings

 

Your Benefits:

  • Bi-directional; measures flow in either direction
  • Very wide dynamic flow range, turndown ratio > 100:1
  • No pressure loss
  • Unaffected by gas contaminants and wetness
  • Unaffected by noise of valves or compressors
  • Accurate and reproducible, even at low flow rates
  • Outstanding long-term stable accuracy
  • Works independently of the conductivity and pressure of the medium
  • Fits all pipe sizes and works on thick pipe walls
  • Measurement in actual and normalized gas volume units
  • Robust measurement systems, even for use in offshore applications
  • No risk of leakages
  • No wear and tear, no clogging
  • Certified for hazardous areas; higher levels of operator and plant safety
  • Applicable on pipes with cathodic protection


Technical facts:

Measuring principle: Transit-time difference correlation principle
Flow velocity: 0.03 to >100 ft/s, depending on the pipe size
Repeatability: 0.15% of reading +/- 0.03 ft/s
Accuracy (given a fully developed rotationally symmetric flow profile): Volume flow:
+/- 1% to 3% of reading +/- 0.03 ft/s, depending on the application
+/- 0.5% of reading +/- 0.03 ft/s with field calibration
Pipe size range: 1/4 in to 5 feet
Pipe wall thickness: 0.02 inch up to 2 inch
Operating pressure: No pressure limitations