- About Us
- News & Exhibitions
- Ultrasonic Flowmeters
- Leading Flow Technology
- Your Advantages
- Flowmeters for Liquids
- The multifunctional portable flow meter - F601
- The portable meter for hazardous areas - F608
- The economic water meter - ADM 5107
- The permanent meter for all liquids - ADM 7407
- The permanent Rack flow meter - ADM 7907
- The permanent meter for hazardous areas - ADM 8027
- The permanent meter for Offshore environments - ADM 8127
- Flowmeters for Gases
- The portable gas flow meter - G601
- The portable gas and liquids flow meter - G601 CA Energy
- The portable gas flow meter for hazardous environments - G608
- The permanent gas flow meter - G704
- The permanent Rack gas flow meter - G709
- The permanent gas flow meter for hazardous areas - G800
- The permanent gas flow meter for Offshore environments - G801
- BTU - Thermal Energy Metering
- Process Analysis
- FLEXIM Oil & Gas
- Refinery
- State-of-the-Art
- Advantages & Benefits
- Field-Proven Worldwide
- Heavy Crude Oil flow measurement
- Overflash Mass Flow Measurement at 720°F
- Heat Transfer Oil at High Temperatures
- Heavy Gasoil in Vacuum Destillation Tower
- Fluidized Catalytic Cracker
- Highly Viscous Coker and Visbreaker Feed
- Hot Pitch During the Distillation of Coal Tar
- Measurement of Bitumen at 700°F
- Bitumen at Oil Sand Facility
- Portable Measurement of Different Media
- High Temperature Coker Control
- Underground Gas Storage
- Upstream / Offshore
- Refinery
- Service & Documents
- Contact
Unique Features of FLEXIM’s FLUXUS G gas flow meter series:
-
Every set of transducers is wet-calibrated and supplied with a traceable calibration certificate
- Capable of measuring wet gas
- Virtually maintenance-free due to permanent coupling pads
- Transmitter supports both shear wave and Lamb wave transducers
- Compliant with ANSI/ASME MFC-5M-1985(R2001) (temperature compensation)
- Up to 1000 measuring cycles per second guarantee stable and precise flow readings
Your Benefits:
- Bi-directional; measures flow in either direction
- Very wide dynamic flow range, turndown ratio > 100:1
- No pressure loss
- Unaffected by gas contaminants and wetness
- Unaffected by noise of valves or compressors
- Accurate and reproducible, even at low flow rates
- Outstanding long-term stable accuracy
- Works independently of the conductivity and pressure of the medium
- Fits all pipe sizes and works on thick pipe walls
- Measurement in actual and normalized gas volume units
- Robust measurement systems, even for use in offshore applications
- No risk of leakages
- No wear and tear, no clogging
- Certified for hazardous areas; higher levels of operator and plant safety
- Applicable on pipes with cathodic protection
Technical facts:
| Measuring principle: | Transit-time difference correlation principle |
| Flow velocity: | 0.03 to >100 ft/s, depending on the pipe size |
| Repeatability: | 0.15% of reading +/- 0.03 ft/s |
| Accuracy (given a fully developed rotationally symmetric flow profile): |
Volume flow: +/- 1% to 3% of reading +/- 0.03 ft/s, depending on the application +/- 0.5% of reading +/- 0.03 ft/s with field calibration |
| Pipe size range: | 1/4 in to 5 feet |
| Pipe wall thickness: | 0.02 inch up to 2 inch |
| Operating pressure: | No pressure limitations |