- About us
- News & Exhibitions
- Ultrasonic Flowmeters
- Leading Flow Technology
- Your Advantages
- Flowmeters for Liquids
- The multifunctional portable meter - F601
- The portable meter for hazardous areas - F608
- The economic water meter - ADM 5107
- The permanent meter for all liquids - ADM 7407
- The permanent Rack flow meter for liquids - ADM 7907
- The permanent meter for hazardous areas - ADM 8027
- The permanent meter for Offshore environments - ADM 8127
- Flowmeters for Gases
- The portable gas flow meter - G601
- The portable gas and liquids flow meter - G601 CA Energy
- The portable gas flow meter for hazardous areas - G608
- The permanent gas flow meter - G704
- The permanent Rack gas flow meter - G709
- The permanent gas flow meter for hazardous areas - G800
- The permanent gas flow meter for Offshore environments - G801
- BTU - Energy Metering
- Process Analysis
- FLEXIM Oil & Gas
- Refinery
- Advantages & Benefits
- State-of-the-Art
- Field-Proven Worldwide
- Heavy Crude Oil flow measurement
- Overflash Mass Flow Measurement at 380°C
- Heat Transfer Oil at High Temperatures
- Heavy Gasoil in Vacuum Destillation Tower
- Fluidized Catalytic Cracker
- Highly Viscous Coker and Visbreaker Feed
- Hot Pitch During the Distillation of Coal Tar
- Measurement of Bitumen at 370°C
- Bitumen at Oil Sand Facility
- Portable Measurement of Different Media
- High Temperature Coker Control
- Underground Gas Storage
- Upstream / Offshore
- Refinery
- Service & Documents
- Contact
Heavy Crude Oil flow measurement
Heavy Crude Oil flow measurement
Due to the extreme process conditions and the high requirements for reliability in refineries, most flow measuring points are still conventionally fitted with wetted mechanical measuring equipment which works according to Bernoulli's pressure difference principle. However, even these simple and supposedly sound measuring instruments have been prone to malfunction and are potential sources of danger in practice.
A particular difficulty involved in the measurement process in all refineries is the flow measurement of heavy crude oil fractions. These highly viscous hydrocarbon mixtures, which must be heated to temperatures above 350°C, so that they can remain capabale of flowing, often block the thin impulse lines of aperature measurements. This results in extensive maintenance costs with associated downtimes of plant sections.
For these reasons, a large oil producer and operator of refineries in the Middle East was looking for basic alternatives to conventional measuring technologies.
Non-intrusive clamp-on ultrasonic flow measurement with the FLUXUS ADM 8027 and the high temperature WaveInjector mounting proved to be the best solution during comprehensive testing.
Since the flow transducers are attached to the outside of the pipe, they are not subject to wear and tear from the medium flowing in the pipe. The measuring equipment can be installed and set-up without any pipe work and during ongoing operation.
After two years of trouble free trial operation, the refinery operator decided to fit entire plant sections with the FLUXUS ADM 8027 and WaveInjector measuring equipment. More than 20 dual channel FLUXUS ADM 8027 and more than 40 WaveInjectors are now used in the refinery.
Your Benefits:
-
Reliable, non-intrusive and practically maintenance free flow measurement with high measuring dynamics
-
Increased operating safety
-
Installation during ongoing operation
-
Constant plant availability
-
No pressure loss
-
No risk of leakages
-
Certified transmitters and transducers for operation in potentially explosive areas.