- About us
- News & Exhibitions
- Ultrasonic Flowmeters
- Leading Flow Technology
- Your Advantages
- Flowmeters for Liquids
- The multifunctional portable meter - F601
- The portable meter for hazardous areas - F608
- The economic water meter - ADM 5107
- The permanent meter for all liquids - ADM 7407
- The permanent Rack flow meter for liquids - ADM 7907
- The permanent meter for hazardous areas - ADM 8027
- The permanent meter for Offshore environments - ADM 8127
- Flowmeters for Gases
- The portable gas flow meter - G601
- The portable gas and liquids flow meter - G601 CA Energy
- The portable gas flow meter for hazardous areas - G608
- The permanent gas flow meter - G704
- The permanent Rack gas flow meter - G709
- The permanent gas flow meter for hazardous areas - G800
- The permanent gas flow meter for Offshore environments - G801
- BTU - Energy Metering
- Process Analysis
- FLEXIM Oil & Gas
- Refinery
- Advantages & Benefits
- State-of-the-Art
- Field-Proven Worldwide
- Heavy Crude Oil flow measurement
- Overflash Mass Flow Measurement at 380°C
- Heat Transfer Oil at High Temperatures
- Heavy Gasoil in Vacuum Destillation Tower
- Fluidized Catalytic Cracker
- Highly Viscous Coker and Visbreaker Feed
- Hot Pitch During the Distillation of Coal Tar
- Measurement of Bitumen at 370°C
- Bitumen at Oil Sand Facility
- Portable Measurement of Different Media
- High Temperature Coker Control
- Underground Gas Storage
- Upstream / Offshore
- Refinery
- Service & Documents
- Contact
FLUXUS® G800 - The Gas Flow Meter for permanent installation in hazardous areas
The Explosion-proof Expert
The FLUXUS G800 is the ideal gas flow meter for permanent installation in potentially explosive atmospheres (ATEX (IECEx) approved for Zone 1). With its flameproof housing (IP66) the gas flow meter is designed for industrial use in harsh environments such as in gas processing plants and natural gas extraction or the chemical and petrochemical industry.
The FLUXUS G800 gas flow meter allows for an inherently bi-directional gas flow measurement of operational and standard volume flows. As the transducers are mounted on the outside of the pipe wall, the system does not suffer from wear and tear or clogging, can't be a risk for leaks and will not cause any pressure drops inside the pipe.
Due to its matched and paired transducers as well as the internal temperature compensation (compliant to ANSI/ASME) the measurement system is drift free and zero stable ensuring accurate readings. Moreover, as the transducer calibration data is automatically loaded by connecting the transducer to the transmitter, set-up times are reduced and precise, long-term stable results are provided.
The gas flow meter can be applied at inner pipe diameters ranging from 7mm up to 1600mm (no limitations on pipe wall thickness or material) and media temperatures from -30°C up to 200°C. Moreover, the measurement system is independent of the pressure inside the pipe.
With up to two measurement channels, the FLUXUS G800 permanent gas flow meter can also be applied to difficult measurement points and is completely unaffected by gas density, viscosity and composition as well as temperature and pressure. Even wet gas up to Liquid Volume Fractions of 5% can be measured.
Applications
Gas processing, natural gas extraction, gas transport and storage
- Measurement on natural gas pipelines and in natural gas storage installations
- Measurement of synthesized gas and injection gas
- Measurement for the gas utilities industry
Chemical Industry
Petrochemical Industry
Technical facts:
| FLUXUS G800 permanent gas flow meter for hazardous areas | |
| Operating temperature of transmitter: | -20°C ... 50°C |
| Measuring channels: | 1 or 2 |
| Protection degree (acc. to EN60529): | IP66 |
| Hazardous area classification: | ATEX Zone 1 and 2 |
| Inputs: | - |
| Outputs: | 1 current output, 1 binary output (OC). Also available: 1 or 2 binary outputs (relay), 1 binary output (OC) and 1 current output |
| Calculation of the standard volume flow based on AGA-8 / ISO 12213-1: | Yes |
| Communication protocol: | HART |
| Media temperature: | -40°C ... 200°C |
| Pipe diameter range: | 7mm ... 1600mm |
| Operating pressure range: | no limitation |
| Flow velocity range: | 0,01 ... 35 m/s (dependent on pipe size) |
| Measurement accuracy: |
1% ... 3% of reading +/- 0,01 m/s, depending on application 0,5% of reading +/- 0,01 m/s, field calibrated |
Typical Applications
- Chemical Industry
- Gas Exploration and Production
- Gas Storage
- Gas Transport
- Industrial Parks
- Natural gas pipelines