- About us
- News & Exhibitions
- Ultrasonic Flowmeters
- Leading Flow Technology
- Your Advantages
- Flowmeters for Liquids
- The multifunctional portable meter - F601
- The portable meter for hazardous areas - F608
- The economic water meter - ADM 5107
- The permanent meter for all liquids - ADM 7407
- The permanent Rack flow meter for liquids - ADM 7907
- The permanent meter for hazardous areas - ADM 8027
- The permanent meter for Offshore environments - ADM 8127
- Flowmeters for Gases
- The portable gas flow meter - G601
- The portable gas and liquids flow meter - G601 CA Energy
- The portable gas flow meter for hazardous areas - G608
- The permanent gas flow meter - G704
- The permanent Rack gas flow meter - G709
- The permanent gas flow meter for hazardous areas - G800
- The permanent gas flow meter for Offshore environments - G801
- BTU - Energy Metering
- Process Analysis
- FLEXIM Oil & Gas
- Refinery
- Advantages & Benefits
- State-of-the-Art
- Field-Proven Worldwide
- Heavy Crude Oil flow measurement
- Overflash Mass Flow Measurement at 380°C
- Heat Transfer Oil at High Temperatures
- Heavy Gasoil in Vacuum Destillation Tower
- Fluidized Catalytic Cracker
- Highly Viscous Coker and Visbreaker Feed
- Hot Pitch During the Distillation of Coal Tar
- Measurement of Bitumen at 370°C
- Bitumen at Oil Sand Facility
- Portable Measurement of Different Media
- High Temperature Coker Control
- Underground Gas Storage
- Upstream / Offshore
- Refinery
- Service & Documents
- Contact
The Offshore Flow Meter - The FLUXUS® ADM 8127
FLUXUS ADM 8127 - The ultrasonic flow meter for Offshore and Mining applications
The FLUXUS ADM 8127 flow meter for liquids is FLEXIM's solution for explosion hazard environments Offshore (being ATEX (IECEx) approved for usage in zones 1 and 2).
With a flameproof field-enclosure made entirely of stainless steel, the flow meter is permanently seaspray and seawater proof and can easily be operated by a magnet pen without having to open the housing.
The FLUXUS ADM 8127 flow meter allows for an inherently bi-directional flow measurement of volume and mass flow rates of nearly any liquid media - ranging form crude oil to refined products - and can be equipped with various outputs to be used for a sophisticated process control. As the ultrasonic transducers are mounted on the outside of the pipe wall, enclosed in the rugged stainless steel VARIOFIX C mounting fixture, the system does not suffer from wear, tear or clogging and can't be a risk for leaks.
Due to its matched and paired transducers as well as the internal temperature compensation (compliant to ANSI/ASME regulations), the measurement system is drift free and zero stable. Moreover, as the transducers calibration data is automatically loaded by connecting the transducer to the transmitter, set-up times are significantly reduced. As of its exceptional dual-uP technology, the high number of measuring cycles per second and the adaptive signal processing, the FLUXUS ADM 8127 flow meter produces stable and reliable measuring results even under the most difficult conditions.
The ADM 8127 flow meter can be applied at inner pipe diameters ranging from 10 mm up to 6500 mm (no limitations on pipe wall thickness or material) and media temperatures from -40°C up to 400°C (by usage of the high temperature mounting fixture WaveInjector).
With up to two measurement channels, the FLUXUS ADM 8127 flow meter can also be applied to difficult measurement points with non-ideal flow profiles. Even liquid streams with a high content of solids or gas bubbles are not a problem due to the innovative HybridTrek mode implemented into the flow computer.
Applications:
Oil exploration and extraction
- Flow measurement of injection media, e.g. methanol
- Flow measurement of injected and produced water
- Flow Measurement at Separators
- Measurement of the feeding process into sand separators for process management
- Flow measurement of condensate
- Measurement on high pressure systems
- and more.
Mining Industry
- For use in explosive atmosphere areas in the underground mining (Equipment group I, category M2)
Technical Facts:
| FLUXUS ADM 8127 - Offshore Flow Meter for hazardous areas | |
|---|---|
| Temperature range of the transmitter: | -20°C...50°C |
| Flow channels: | 1 or 2 |
| Protection degree (acc. to EN60529): | IP 66 (Transmitter) |
| Hazardous area classification: | ATEX zone 1 and 2; ATEX mining certification optional |
| Outputs: | 1 current, 1 binary (OC) |
| Also available: | 1 or 2 binary outputs (relay), 1 binary (OC) and 1 current, 1 binary (OC) and 1 frequency |
| Communication Protocol: | HART, Modbus, RS485 |
| Media temperature: | -40°C ... 400°C (High Temperature WaveInjector mounting fixture) |
| Pipe diameter range: | 10 mm ... 6500 mm |
| Flow velocity range: | 0,01 ... 25 m/s |
| Measurement accuracy: |
±1.2 % of reading ±0.01 m/s (extended calibration) ±0,5% of reading +/- 0,01 m/s, field calibrated |
| Corrosion-proof and seawater-proof flow meter; resistant to saltwater mist | |
|
Connection enclosure and electronics enclosure of the flow meter are hermetically sealed, Connection compartment: increased safety, Output circuits: intrinsic safety 240V or 24V DC power supply version of the transmitter available |
|
Typical Applications
- Mining industry
- Oil and Gas Industry
- Oil exploration and production Offshore and Onshore